23
Sat, Nov
1 New Articles

Your Dial-up SDLC Connection

Typography
  • Smaller Small Medium Big Bigger
  • Default Helvetica Segoe Georgia Times

Let's suppose you're an AS/400 manager at a middle market company that has just bought out a competitor that also uses OS/400.

One day, the president E-mails you and writes, "...We really need access to the new company's AS/400. Nothing fancy. Just let us dig into their books. Oh, and we need it to prepare for next week's shareholder's meeting."

Being an intelligent MIS manager, you E-mail back the answer any intelligent MIS manager gives in this situation: "No problem."

Fortunately, there is a way out. You can use an old, reliable dial-up connection that IBM gave you free. It configures easily, uses existing telephone lines and modems, and isn't a major hassle to run. It's a dial-up SDLC connection, and it's so easy to set up that you can do it while watching a presidential address or the Super Bowl...or in your sleep, whichever comes first.

Interested? Well, if you're the poor MIS manager in this article, you probably don't have much time, so I'll get started.

In this situation, there is no time for setting up a SNADS configuration. You must quickly establish a telecommunications link between two AS/400s for data viewing. I'll focus on the practical aspects of using your existing telecommunications equipment, configuring the AS/400 communications lines on both machines, connecting the two machines through SDLC, and providing display station passthrough (DSPT) access.

Later, when this basic configuration is set up, you can focus on adding remote system printing, Client Access support, and file and message forwarding functions to the connection. You add some of these functions by setting up a SNADS configuration between the two machines that will run over your SDLC line. While not difficult to configure, a SNADS configuration is harder to understand and troubleshoot than this SDLC connection.

You probably have everything you need to set up a basic SDLC connection. For this example, you need an IBM-approved SDLC-capable modem and a phone line that supports incoming and outgoing calls.

For a quick configuration between two AS/400s, you can use the Electronic Customer Support (ECS) modem installed on your machine to download PTFs. In many cases, this modem is not used very often and is the perfect candidate for an SDLC connection. By using the ECS modem, you save yourself the time and expense of ordering additional SDLC modems, such as the IBM 7855, and installing them on your AS/400 and the AS/400 you're connecting to.

There is one pitfall in this approach, and it can hit you hard unexpectedly. Using the ECS modem for communications with another office will necessarily limit your ability to use the modem for ECS. Normally, this is not a big problem as most people use ECS infrequently. Its usage can be bumped over to off hours when you won't need the inter-AS/400 connection. The situation can be difficult, however, when your entire shop is waiting for something to come in over ECS and your internal users won't let you sever the connection. I recommend using the supplied ECS modems to set up the connection and then, once everything is stable, adding an additional modem, communications adapter, and phone line to both locations to be used just for the inter-AS/400 connection.

1 shows you most of the information you'll need from both machines to create an SDLC connection. (In the example in this article, I'm connecting system MCPGMR to system MC.) You can get this information by running the Display Network Attributes (DSPNETA) command and selecting the *PRINT option. You must run this command on each machine to get both sets of parameters.

Figure 1 shows you most of the information you'll need from both machines to create an SDLC connection. (In the example in this article, I'm connecting system MCPGMR to system MC.) You can get this information by running the Display Network Attributes (DSPNETA) command and selecting the *PRINT option. You must run this command on each machine to get both sets of parameters.

The only other pieces of information you'll need are the phone numbers of the ECS modem lines on each machine and the AS/400 resource names the ECS modems are attached to. The resource name is simply the AS/400 hardware address of the communication card your ECS modem is hooked up to. For most machines, the ECS port number is LIN011. To find this address, run the Display Line Description (DSPLIND) command on your ECS line (often called QESLINE); the address is the value in the Resource names (RSRCNAME) parameter.

Armed with this information, you can do the configuration.

As I mentioned, IBM gives you a basic SDLC configuration free with OS/400. There isn't a lot of work involved in setting up terminal access between two AS/400s in different locations. Most of the work is done through the Communications Configuration Tasks menu. You access this menu by typing in the following command:

 GO CMNCFG 

CMNCFG is a simple but powerful menu for creating communication lines to contact remote systems using SDLC, token-ring, or Ethernet lines. This menu can create line and controller configurations over a network, through dedicated (nonswitched) phone lines, or through dial-up lines. You can also use it to create configurations for accessing remote workstation controllers.

You must use the CMNCFG menu options on both AS/400s, but it doesn't matter which AS/400 you configure first. As you'll see, the configuration for the second AS/400 is dependent on the values you enter for the first system.

2 shows the Communications Configuration Tasks screen, the first of a series of screens that guide you through the configuration process. On the first machine you configure, select option 2, Remote systems, from the menu.

Figure 2 shows the Communications Configuration Tasks screen, the first of a series of screens that guide you through the configuration process. On the first machine you configure, select option 2, Remote systems, from the menu.

Selecting option 2 brings up the Configure to Remote Systems screen shown in 3. On the line description display, type in 1 and the name of the SDLC line you want to create. In the example, to create an SDLC line that allows the local machine to call the remote machine, you type 1 and specify MC as the name of the line you want to create.

Selecting option 2 brings up the Configure to Remote Systems screen shown in Figure 3. On the line description display, type in 1 and the name of the SDLC line you want to create. In the example, to create an SDLC line that allows the local machine to call the remote machine, you type 1 and specify MC as the name of the line you want to create.

The menu will then prompt you for specific information about the line you want to create (see 4). It will ask you if you want to create a multipoint, a nonswitched point-to-point, or a switched point-to-point SDLC line. Since you are running the connection on nondedicated switched lines, choose option 3, SDLC switched point-to-point, and press Enter.

The menu will then prompt you for specific information about the line you want to create (see Figure 4). It will ask you if you want to create a multipoint, a nonswitched point-to-point, or a switched point-to-point SDLC line. Since you are running the connection on nondedicated switched lines, choose option 3, SDLC switched point-to-point, and press Enter.

The next screen, as shown in 5, allows you to specify the AS/400 communications port you want to use. Another series of prompts, shown in6 and 7, asks you for the following four parameters. Here, it's fairly easy to get confused and enter a wrong value, so be careful.

The next screen, as shown in Figure 5, allows you to specify the AS/400 communications port you want to use. Another series of prompts, shown in Figures 6 and 7, asks you for the following four parameters. Here, it's fairly easy to get confused and enter a wrong value, so be careful.

Local system telephone number is the phone number of the system you are dialing from. This is not important for dialing out to the remote system, but it does become important when it's time to configure the remote system. What you enter here will be printed in the instructions for configuring the remote system.

Remote system name is the default local location name from the DSPNETA list you printed for the system you are connecting to.

Remote system type specifies whether the system you are calling is an AS/400 or a S/36.

Remote system telephone number is the phone number your AS/400 dials when it uses the SDLC line to call the remote system.

After entering these parameters, press Enter. A new SDLC communications line is created, and the display tells you to look for printed instructions on configuring the remote system for SDLC use. These printed instructions are so clear and easy to use that you could fax them to the remote location and let the local staff there configure that SDLC line; however, I'll proceed as though you're configuring the remote system.

At the remote AS/400, use the printed configuration instructions and type in the GO CMNCFG command again. This time, though, select option 3, Remote systems using printed instructions (see 2). Then follow the printed instructions, and a second line will be created on the remote system that can be used in SDLC communications.

At the remote AS/400, use the printed configuration instructions and type in the GO CMNCFG command again. This time, though, select option 3, Remote systems using printed instructions (see Figure 2). Then follow the printed instructions, and a second line will be created on the remote system that can be used in SDLC communications.

When you complete the instructions for the remote system, you will have set up a connection between the two systems, complete with communications lines and all the necessary controller configurations. To connect to the remote system, start a passthrough session using the local location name of the system you want to connect to. For example, to start a session on the remote system from the local system, you would enter the following command:

 STRPASTHR MC 

If the machines are not already connected by an SDLC line, the local AS/400 dials the remote AS/400 and initiates a session. A passthrough session running over the SDLC line performs the connection. Once the session is active, any user on either AS/400 can start another session by using the active SDLC line to initiate a different passthrough session on the other machine.

To disconnect from the remote machine, the user can end passthrough by issuing the following command:

 ENDPASTHR 

This command disconnects the user's individual session from the remote machine. If other people are using passthrough between the two machines, however, the SDLC connection will remain active. When the last person using the connection signs off, the dial-up SDLC connection is severed. It is reestablished the next time someone requests a passthrough session on either machine.

Once you have a simple SDLC connection set up, your users will begin looking for more services from the connected AS/400. Remember that the configuration outlined here is just for terminal emulation between two AS/400s. It provides nothing else.

Getting other inter-AS/400 features-such as remote printer support, file exchange, and message exchange-may require a SNADS configuration between the two systems. A SNADS configuration is more complicated than the simple configuration outlined here, and there is no centralized menu for setting one up. For more information on how to configure SNADS, see "Getting Started with SNADS," MC, May 1994.

When all you need is basic terminal support between two AS/400s, it's hard to beat an SDLC configuration for ease of setup and ease of use. So, the next time your president calls up with a seemingly impossible demand to hook up two AS/400s quickly over a dial-up line, just say, "No problem."

Editor's Note: This article was originally written and tested using two AS/400s at V3R0M5, and everything worked as described. When we tested the configuration procedures here at MC, we used V3R1. During our testing, we encountered some problems getting the modem to dial when it was supposed to (at the time you run the STRPASTHR command). We contacted IBM, and they confirmed that there are problems with dial-up SDLC connections in V3R1. By the time you read this, one or more PTFs should be available. If you're at V3R1, be sure your systems are up-to-date with the latest cumulative PTF tape.

Joe Hertvik is a freelance writer and a system administrator for a manufacturing company outside of Chicago.

Your Dial-up SDLC Connection

Figure 1: Sample Display Network Attributes (DSPNETA) Report


Your Dial-up SDLC Connection

Figure 2: The Communications Configuration Tasks Screen


Your Dial-up SDLC Connection

Figure 3: The Configure to Remote Systems Screen


Your Dial-up SDLC Connection

Figure 4: Selecting a Line Type


Your Dial-up SDLC Connection

Figure 5: Selecting a Communications Port


Your Dial-up SDLC Connection

Figure 6: Entering the Local System Telephone Number


Your Dial-up SDLC Connection

Figure 7: Entering the Remote System Information


BLOG COMMENTS POWERED BY DISQUS

LATEST COMMENTS

Support MC Press Online

$

Book Reviews

Resource Center

  • SB Profound WC 5536 Have you been wondering about Node.js? Our free Node.js Webinar Series takes you from total beginner to creating a fully-functional IBM i Node.js business application. You can find Part 1 here. In Part 2 of our free Node.js Webinar Series, Brian May teaches you the different tooling options available for writing code, debugging, and using Git for version control. Brian will briefly discuss the different tools available, and demonstrate his preferred setup for Node development on IBM i or any platform. Attend this webinar to learn:

  • SB Profound WP 5539More than ever, there is a demand for IT to deliver innovation. Your IBM i has been an essential part of your business operations for years. However, your organization may struggle to maintain the current system and implement new projects. The thousands of customers we've worked with and surveyed state that expectations regarding the digital footprint and vision of the company are not aligned with the current IT environment.

  • SB HelpSystems ROBOT Generic IBM announced the E1080 servers using the latest Power10 processor in September 2021. The most powerful processor from IBM to date, Power10 is designed to handle the demands of doing business in today’s high-tech atmosphere, including running cloud applications, supporting big data, and managing AI workloads. But what does Power10 mean for your data center? In this recorded webinar, IBMers Dan Sundt and Dylan Boday join IBM Power Champion Tom Huntington for a discussion on why Power10 technology is the right strategic investment if you run IBM i, AIX, or Linux. In this action-packed hour, Tom will share trends from the IBM i and AIX user communities while Dan and Dylan dive into the tech specs for key hardware, including:

  • Magic MarkTRY the one package that solves all your document design and printing challenges on all your platforms. Produce bar code labels, electronic forms, ad hoc reports, and RFID tags – without programming! MarkMagic is the only document design and print solution that combines report writing, WYSIWYG label and forms design, and conditional printing in one integrated product. Make sure your data survives when catastrophe hits. Request your trial now!  Request Now.

  • SB HelpSystems ROBOT GenericForms of ransomware has been around for over 30 years, and with more and more organizations suffering attacks each year, it continues to endure. What has made ransomware such a durable threat and what is the best way to combat it? In order to prevent ransomware, organizations must first understand how it works.

  • SB HelpSystems ROBOT GenericIT security is a top priority for businesses around the world, but most IBM i pros don’t know where to begin—and most cybersecurity experts don’t know IBM i. In this session, Robin Tatam explores the business impact of lax IBM i security, the top vulnerabilities putting IBM i at risk, and the steps you can take to protect your organization. If you’re looking to avoid unexpected downtime or corrupted data, you don’t want to miss this session.

  • SB HelpSystems ROBOT GenericCan you trust all of your users all of the time? A typical end user receives 16 malicious emails each month, but only 17 percent of these phishing campaigns are reported to IT. Once an attack is underway, most organizations won’t discover the breach until six months later. A staggering amount of damage can occur in that time. Despite these risks, 93 percent of organizations are leaving their IBM i systems vulnerable to cybercrime. In this on-demand webinar, IBM i security experts Robin Tatam and Sandi Moore will reveal:

  • FORTRA Disaster protection is vital to every business. Yet, it often consists of patched together procedures that are prone to error. From automatic backups to data encryption to media management, Robot automates the routine (yet often complex) tasks of iSeries backup and recovery, saving you time and money and making the process safer and more reliable. Automate your backups with the Robot Backup and Recovery Solution. Key features include:

  • FORTRAManaging messages on your IBM i can be more than a full-time job if you have to do it manually. Messages need a response and resources must be monitored—often over multiple systems and across platforms. How can you be sure you won’t miss important system events? Automate your message center with the Robot Message Management Solution. Key features include:

  • FORTRAThe thought of printing, distributing, and storing iSeries reports manually may reduce you to tears. Paper and labor costs associated with report generation can spiral out of control. Mountains of paper threaten to swamp your files. Robot automates report bursting, distribution, bundling, and archiving, and offers secure, selective online report viewing. Manage your reports with the Robot Report Management Solution. Key features include:

  • FORTRAFor over 30 years, Robot has been a leader in systems management for IBM i. With batch job creation and scheduling at its core, the Robot Job Scheduling Solution reduces the opportunity for human error and helps you maintain service levels, automating even the biggest, most complex runbooks. Manage your job schedule with the Robot Job Scheduling Solution. Key features include:

  • LANSA Business users want new applications now. Market and regulatory pressures require faster application updates and delivery into production. Your IBM i developers may be approaching retirement, and you see no sure way to fill their positions with experienced developers. In addition, you may be caught between maintaining your existing applications and the uncertainty of moving to something new.

  • LANSAWhen it comes to creating your business applications, there are hundreds of coding platforms and programming languages to choose from. These options range from very complex traditional programming languages to Low-Code platforms where sometimes no traditional coding experience is needed. Download our whitepaper, The Power of Writing Code in a Low-Code Solution, and:

  • LANSASupply Chain is becoming increasingly complex and unpredictable. From raw materials for manufacturing to food supply chains, the journey from source to production to delivery to consumers is marred with inefficiencies, manual processes, shortages, recalls, counterfeits, and scandals. In this webinar, we discuss how:

  • The MC Resource Centers bring you the widest selection of white papers, trial software, and on-demand webcasts for you to choose from. >> Review the list of White Papers, Trial Software or On-Demand Webcast at the MC Press Resource Center. >> Add the items to yru Cart and complet he checkout process and submit

  • Profound Logic Have you been wondering about Node.js? Our free Node.js Webinar Series takes you from total beginner to creating a fully-functional IBM i Node.js business application.

  • SB Profound WC 5536Join us for this hour-long webcast that will explore:

  • Fortra IT managers hoping to find new IBM i talent are discovering that the pool of experienced RPG programmers and operators or administrators with intimate knowledge of the operating system and the applications that run on it is small. This begs the question: How will you manage the platform that supports such a big part of your business? This guide offers strategies and software suggestions to help you plan IT staffing and resources and smooth the transition after your AS/400 talent retires. Read on to learn: